INDEX CHINESE About us Products Achievement Feedback Contact
 Electric trace heater
 Electric heating  designing
 Electric heating meter  tube
 Electric heating meter  case
 LVself-regulating & low  temperature electric  heating cable
 HVself-regulating &  middle temperature
 electric heating cable
 HHV self-regulating &  high temperature
 electric heating cable
 CWM unvarying-power &  middle temperature  electric heating cable
 CWH unvarying-power &  middle temperature  electric heating cable
 MI electric heating  cable
 SRCM series connection  electric heating cable
 Collect skin effect  electricity accompanies
 heat series
 Electric control
 Installing sketch map
 Other electric heating  forms and methods
 Electric heater
 Flange heater
 Immerge heater
 The heater of store  pots types that offer
 pump
 The heater of Unload  and press the gas
 The heater of store pot
 The heater of panel
 The gas heater of wind
 The heater of 200L  jerrican
 The heater system of hot carrier
 The electricity heater  of the steam boiler
 The temperature control  system
 The document of electric  heating designing
 The meaning of defending  rate symbol
 The common sense of  explosion protection
 equipment
 Accessories
 
Position >>> Products
  HHV self-regulating & high temperature electric heating
cable
 
Specification      
Self-regulating and save energy  
16 AWG Conductor
Rated Voltage 220V/110V
Max Using Length 69 m
Max Heating Temperature 190℃
the most Enduring heating Temperature 232℃
Local Cutting at random
60W/m,75W/m,90 W/m
Min. Bending Radius 30mm
Fitting for Explosion Protection Area 1、2
       
A Conductor
B Semiconductor Heating Core
C Inner Jacket,Improving FI
Plastic

D Tinned Copper Meshing,nickel,chrome, copper or Stainless Steel Meshing

 
E FI Plastic Outer Jacket
Power Amending Quotiety
NO. 208V 277V
20HHV 0.94 1.08
30HHV 0.99 1.01
The cable using length for corresponding breaker Unit: Meter  
Cable
Type
Openning Temp.10℃ Openning Temp.20℃ Openning Temp.-45℃
15A 20A 30A 15A 20A 30A 15A 20A 30A
20HHV-2SJ 34 45 69 33 43 66 31 42 63
25HHV-2SJ 27 36 51 24 30 48 24 30 48
30HHV-2SJ 24 30 42 21 27 42 21 27 42
Suggestion: PLS using the breaker, which has hot put-off. For put-off
breaker can avoid the mistake while the temperature is low.
Type Number Nomenclature      
       
 
Add: Jianzhu Road Qiuxiang 518# Wuxi City Jiangsu Province    214062
Tel:0510-85137261    0510-85117922       Fax:0510-85124215
Website Technical support: Wuxi Shichuang InfoTech Co., Ltd.